TRANSFORMERS
ÒÌ 25-1000 kVA 6-10 kV
ÒÌ 160-630 kVA 20-35 kV
ÎÌ 25, 40 kVA 6, 10 kV
Three-phase (typeTM) and single-phase (type OM) oil-immersed step-down transformers are intended for power distribution in continuous operation under temperate or tropical climate conditions. The transformers are suitable for working indoors or outdoors in agriculture, industry and town networks.
Off-circuit tap changing: five taps for +2.5% and ±5% on H.V. winding. Rated frequency: 50 or 60 c.p.s. The transformers can be manufactured with other voltage combinations and winding connections upon request.
Transformer type
|
Power, kVA
|
High voltage, kV
|
Low voltage, kV
|
Winding connection (vector group)
|
ÒÌ |
25; 40; 63 |
6,0; 10,0 |
0,23; 0,4; 0,415; 0,42; 0,44 |
Y / yn-O
Y / zn-11
D / yn-11 |
100; 160; 250; 400; 630 |
5,5; 6,0; 6,3; 6,6; 10,0; 10,5; 11,0; 15,0; 20,0; 35,0 |
1000 |
6,0 or 10,0 |
0,4 |
ÎÌ |
25; 40 |
6,0 or 10,0 |
0,22 |
I / I - O |
TRANSFORMER SUBSTATIONS
PKTPM, PKTP
KTP
KTPN, KTPS |
250-630 KVA
25-400 KVA
25-160 KVA |
611 KV
611 KV
6, 10 KV |
ÊÒÏ and ÏÊÒÏ series prefabricated transformer substations are intended for connection to three-phase H.V. lines, for stepping-down a voltage and distributing a power to consumers' feeders.
The substations are suitable for operating in town lines, agriculture, industry, mines, building platforms and gas-supply stations.
ÊÒÏ stationary, indoor
ÊÒÏÍ stationary, outdoor
ÊÒÏÑ pole, outdoor
2ÊÒÏ two-transformer modification, indoor
ÏÊÒÏ and ÏÊÒÏÌ portable, outdoor
Neutral conditions:
ÊÒÏ, ÊÒÏÍ and ÊÒÏÑ earthed
ÏÊÒÏ and ÏÊÒÏÌ insulated or earthed
Mains frequency: 50 or 60 c. p. s.
Substation type
|
Power, kVA |
Hight voltage, kV
|
Low voltage, kV
|
Feeder switches, Ampere x amount
|
Connections to power lines
|
Weight, kg
|
ÊÒÏ
|
25 |
6,0; 6,6; 10; 11 |
0,4; 0,42; 0,44 |
16x1; 25x1; 40x1 |
Cable input on HV and LV sides |
1085 |
40 |
25x1; 40x1; 63x1 |
1215 |
63 |
40x1; 63x1; 100x1 |
1360 |
100 |
63x1; 100x1; 160x1 |
1400 |
160 |
100x1; 160x1; 250x1 |
1694 |
250 |
160x2; 250x1 |
1820 |
400 |
160x2; 250x2; 400x1 |
2270 |
ÊÒÏÍ
|
25 |
6,0 or 10 |
0,4 |
16x1; 25x1; 40x1 |
Cable input on HV and LV sides
|
1185 |
40 |
25x1; 40x1; 63x1 |
1320 |
63 |
40x1; 63x1;100x1 |
1470 |
100 |
63x1; 100x1; 160x1 |
1510 |
160 |
100x1; 160x1; 250x1 |
1800 |
ÊÒÏÑ
|
25 |
6,0 or 10 |
0,4 |
16x1; 25x1; 40x1 |
Aerial line input on HV side and aerial or cable line input on LV side
|
1050 |
40 |
25x1; 40x1; 63x1 |
1200 |
63 |
40x1; 63x1; 100x1 |
1260 |
100 |
63x1; 100x1; 160x1 |
1310 |
160 |
100x1; 160x1; 250x1 |
1540 |
2ÊÒÏ
|
250 |
6,0; 6,6; 10; 11 |
0,4; 0,42; 0,44 |
160x6; 250x3 |
Cable input on HV and LV sides |
3770 |
400 |
160x6; 250x5; 400x2 |
4670 |
ÏÊÒÌÏ
ÏÊÒÌÏ
|
250 |
6,0; 6,6; 10; 11 |
0,4; 0,42; 0,44 |
160x2; 320x2 |
Aerial or cable line input on HV side and cable line input on LV side
|
2330 |
2990 |
400 |
100x2; 250x2
400x1; 630x1 |
2660 |
3400 |
630 |
100x2; 250x2; 630x2 |
3250 |
4000 |
DUCTION MOTORS
DAZO-2 size 16
DAZO-2 size 17
DAZO-2 size 18
DAZO size 19
ÄÀÇÎ and ÄÀÇÎ2 series motors are of three-phase, enclosed, externally forced air cooling design with squirrel-cage rotor and one free shaft end for half-coupling.
The motors are of one-speed and two-speed versions.
The motors are intended for continuous operation as a drive of pumps, smoke exhausters and other mechanisms, which have hard conditions for start.
The motors are suitable for operating outdoors and indoors under temperate climate and tropical climate conditions.
These motors are standard sizes of ÄÀÇÎ2 and ÄÀÇÎ series, which include 90 variants.
Motor type
|
Power, kW |
Voltage, V
|
Frequency of lines c.p.s. |
Synchronous speed RPM |
Weight, kg
|
ÄÀÇÎ2 size 16
|
125-1250 |
3000, 6000, 6600 |
50 or 60 |
500-1500 |
6900-10250 |
ÄÀÇÎ2 size 17 |
200-1250 |
3000, 6000, 6300, 6600 |
50 or 60 |
500-1000 |
7800-11650 |
ÄÀÇÎ2 size 18 |
420-1600 |
6000, 6600 |
50 or 60 |
375-1000 |
15200-17250 |
ÄÀÇÎ size 19 |
360-2500 |
6000, 6600 |
50 |
375-750 |
20500-25500 |
TYPE AD STATIONARY DIESEL-GENERATOR SETS
Voltage 230V or 400V
Frequency 50Hz
Diesel-generator sets are used as a source of AC electrical energy of the high quality in the wide range of load change.
Diesel-generator sets provide operation in ambient temperature changing: from +8 to +50°C.
Self-produced generators (alternator) of SMA and SM series are brushless type.
Diesel - generator sets are completed with control board with emergency protection and fault-warning signalling, are easy - applicable and have electrostart.
50 Hz, 1500 RPM, cos 0.8
Type
|
Voltage, V |
Power, kW |
Engine cooling
|
Specific fuel consumption, g/kW.h |
Weight, kg |
Overall Dimensions LxWxH, mm
|
AD8S-T230(400)-1
|
230 or 400 |
8 |
Air
|
250 |
485 |
1500x650x1380 |
AD10S-T230(400)-1
|
230 or 400 |
10 |
Air
|
250 |
540 |
1465x650x1380 |
AD16S-T230(400)-1
|
230 or 400 |
16 |
Air
|
255 |
620 |
1630x730x1500 |
AD22S-T230(400)-1
|
230 or 400 |
22 |
Air
|
255 |
650 |
1667x730x1500 |
AD30S-T230(400)-1
|
230 or 400 |
30 |
Air-water
|
235 |
860 |
1910x830x1456 |
AD60S-T400-1 |
400 |
60 |
Air-water
|
236 |
1750 |
2350x940x2000 |
AD75S-T400-1 |
400 |
75 |
Air-water
|
250 |
1950 |
2740x900x1550 |
AD100S-T400-1
|
400 |
100 |
Air-water
|
236 |
1840 |
2500x1020x1300 |
ALTERNATORS
2 Pole 4-12KW
4 Pole 4-200KW
Voltage 230 or 400V
Frequency 50 or 60Hz
Power factor 0.8
Series SM (with cast-iron end brackets and frame) and SMA (with welded steel frame and cast-iron end brackets) are designed for operation in stationary and mobile generating sets at voltages 230 or 400 V, 50 or 60 Hz with a power factor of 0.8 (lagging).
The design versions of the alternators are B3 and B3.B5 (other versions are available on request).
Standard enclosure is IP20 (other enclosures are available on request).
The alternators are completely insulated in class "F".
Rated parameters are provided at an ambient temperature from minus 50C to plus 45C at an altitude not above 1000m.
The alternators provide:
-initial self-excitation without an auxiliary power supply
-steady state voltage regulation within 2%;
-sustained short circuit current of not less than 250% of the rated;
-voltage adjustment within the range +5% -10% of the rated;
-transient deviation of voltage with application-rejection of full load less than 20% of the rated;
-linear voltage sine wave distortion factor less than 5%
-temperature deviation of voltage in the process of warming up-1%;
-possibility of starting a squirrel-cage induction motor with rating up to 70% alternator rated output;
-10% power overloads at rated voltage during one hour
-parallel operation with other alternators and mains;
-stator winding is star-connected with neutral brought out, star/delta connections available on request.
|